Part M

Approved Document M: Access to and Use of Buildings

The part of the Building Regulations covering access to and use of buildings, including level thresholds, door widths and accessible facilities. A new extension should not make a dwelling less accessible than it was before.

Read on gov.uk All Approved Documents

Also known as

Part MApproved Document MAD MAccess to and Use of Buildings

What Part M requires for a home project

The Part M requirements and terms the buildwiz guides rely on, with paragraph references where the document gives one. Check the current edition on gov.uk before you build to it.

Limits and figures

Approved Document M minimum socket height for new dwellings
Approved Document M Volume 1 puts switches and socket outlets in new dwellings between 450 mm and 1200 mm above finished floor level (requirement M4(1), para 1.18; the same band applies under optional requirement M4(2), para 2.30) so that people with reduced reach can use them. It applies to new dwellings only: AD M does not apply to an extension of a dwelling (AD M Vol 1 para 0.2), so sockets in an extension can follow the 300 mm convention.
Approved Document M switch mounting height range
Approved Document M Volume 1 puts the centre-line of wall switches in a new dwelling between 450 mm and 1200 mm above finished floor level (requirement M4(1), and optional requirement M4(2)) so that people with reduced reach can operate them. Within that band, 1100-1200 mm is the practical default for ordinary light switches in habitable rooms (above worktop splashback height in kitchens) and 450-1100 mm covers thermostats, video door entry handsets and other accessories. The optional requirements add corner rules: under M4(2), switches and sockets at least 300 mm from an inside corner (para 2.30); under M4(3), for wheelchair user dwellings, 700-1000 mm high and at least 700 mm from an inside corner (para 3.44). AD M does not apply to an extension of a dwelling (para 0.2).
Consumer unit switch height in new dwellings (Approved Document M)
Approved Document M Volume 1 (2015) paragraph 1.18b, requirement M4(1) visitable dwellings: consumer units are mounted so that the switches are 1350 to 1450 mm above floor level. The same wording repeats at 2.30 (M4(2)) and 3.44 (M4(3)). It applies to newly erected dwellings: paragraph 0.2 states the volume does not apply to the extension of a dwelling, and for material alterations the building must be no less compliant with M4(1) than before. For extensions and board changes BS 7671 Regulation 132.12 requires only that equipment is accessible for operation, inspection, testing and maintenance; IET Wiring Matters (Autumn 2013) notes a replacement consumer unit can be moved to a more accessible position.
Socket minimum offset from internal room corner
Conventional minimum horizontal setback from an internal room corner to the nearest socket outlet. Sockets placed closer than this to a corner sit awkwardly behind skirting returns, clash with furniture pushed into the corner, and can foul architrave on adjacent doorways. The 350 mm figure is a trade convention, not a rule: BS 7671 sets no corner distance, and Approved Document M only sets corner distances for new dwellings built to its optional requirements: 300 mm from an inside corner under M4(2) (para 2.30) and 700 mm under M4(3) (para 3.44).
Standard socket height from finished floor (non-worktop rooms)
British industry default socket centreline height from finished floor in living rooms, bedrooms, and other general-purpose spaces. Approved Document M requires a minimum of 450mm for new-build dwellings, but refurb and extension work frequently continues the 300mm convention unless Part M applies. Always specify room-by-room on the socket layout.
UK internal door: standard leaf width
Default door leaf width for UK internal doors. Narrower 610 mm (2 ft) leaves suit cupboards and small WCs; wider 826 mm (2 ft 9 in) leaves are required under Approved Document M for accessible doorways and are increasingly the new-build default. When ordering linings, the opening width must equal leaf width plus two 3 mm side gaps plus twice the lining thickness.

Terms explained

Channel drain
A surface water drainage channel installed flush with paving at the junction between a patio and the house wall. Required when a flush-threshold patio is needed next to bifold or sliding doors to intercept surface water before it reaches the wall, while maintaining DPC clearance.
Consumer Unit
The main electrical distribution board that houses the RCD(s), MCBs and RCBOs protecting individual circuits. Since 1 January 2016, new and replacement domestic consumer units must have a non-combustible enclosure (in practice usually steel) or sit in a non-combustible cabinet (BS 7671 Regulation 421.1.201). A 12-way or 16-way unit is typical for an extension; the electrician will specify the size needed based on the number of circuits.
Digital Spirit Level
An electronic spirit level that uses sensors to display angle in degrees on an LCD screen. Accurate to 0.1mm/m vs 0.5mm/m for quality bubble levels. Audio beep alerts allow hands-free use.
Downstairs WC
A WC (usually with a small basin) on the ground floor of an extended house. Building regulations set no minimum size for one in an extension (Approved Document M Vol 1 para 0.2 excludes extensions), but drainage fall, the distance to the soil stack, ventilation and the escape rules still apply, so its position is a drainage decision before it is a furniture decision.
Laser Level
A device that projects visible laser lines (horizontal, vertical, or both) onto walls and floors. Invaluable for setting kitchen unit heights, aligning tiles, marking picture rails, and checking floor levels across a room. Self-levelling models are easiest to use.
Socket Faceplates
Decorative front plates for electrical sockets, available in single and double configurations. Standard white plastic is cheapest; brushed chrome, stainless steel and matt black finishes are available at higher cost. Choose a consistent style throughout the extension.
Switch Faceplates
Decorative front plates for light switches, available in 1-gang, 2-gang and 3-gang configurations. Same finish ranges as socket faceplates. Dimmer versions available for compatible lighting. Two-way switching requires specific wiring for hall/landing and room entry points.
Transition Strip
A metal, wood, or plastic profile that covers the join between two different floor finishes or accommodates a height difference at the threshold. Must be planned before flooring is laid, not after. Critical at the junction between extension floor and existing house floor.

Pages where Part M comes up

4 guides reference Part M, grouped by build phase.

Want the full picture?

The buildwiz build guides walk through a UK extension in sequence and link to Part M (and every other Approved Document) at the exact stage it bites. That is usually a more productive way to use this material than reading the document cover to cover.