Part G
Approved Document G: Sanitation, Hot Water Safety and Water Efficiency
Sanitation, hot water safety and water efficiency
Also known as
Part GApproved Document GAD GSanitation, Hot Water Safety and Water Efficiency
What Part G requires for a home project
The Part G requirements and terms the buildwiz guides rely on, with paragraph references where the document gives one. Check the current edition on gov.uk before you build to it.
Limits and figures
- Hot water circulating loop minimum temperature (HSE L8 / HSG274)
- Minimum temperature at which hot water should return to the cylinder on a secondary circulation loop to control Legionella colonisation (HSG274 Part 2: at least 50°C, or 55°C in healthcare premises). Approved Document G sets no figure. Colder returns allow biofilm growth in the dead legs. Pairs with the 60°C storage minimum and the 48°C bath delivery maximum.
- Hot water delivery maximum temperature (Part G)
- Maximum temperature of hot water delivered to a fixed bath under Approved Document G requirement G3(4), to prevent scalding. G3(4) applies only to new dwellings and dwellings formed by a material change of use; on a new bath in an extension it is good practice. A thermostatic blending valve (TMV) on the bath supply reduces the 60°C stored temperature down to a safe delivery temperature.
- Hot water storage minimum temperature (HSE L8)
- Minimum temperature at which stored hot water must be held to prevent Legionella colonisation of the cylinder. Applies to unvented cylinders, vented cylinders and thermal stores. The figure comes from HSE ACOP L8 and HSG274; Approved Document G sets no storage minimum (it caps stored water at 100°C).
Terms explained
- Boiling water tap
- A tap that delivers near-instant filtered boiling water via an under-counter tank. Installation requires coordination between three trades: plumber (water supply and waste), electrician (dedicated power socket), and kitchen fitter (undermount clearance). A common scope dispute risk.
- BS EN 806
- Specifications for installations inside buildings conveying water for human consumption, published in five parts covering general requirements, design, pipe sizing, installation, and operation and maintenance. Together with BS 8558 it replaced the withdrawn BS 6700. Approved Document G of the Building Regulations references BS EN 806 and BS 8558 for water installations.
- Gravity-discharging WC
- A WC whose waste runs by fall straight to the drain or soil stack, with no pump. Approved Document G para 4.25 allows a macerator WC only where the dwelling also has access to one of these, which is normally the existing ground-floor WC.
- Immersion Heater
- An electric resistance heating element screwed into a boss on a hot water storage cylinder, used to heat water directly when the boiler is not running. Standard element is 3kW at 240V, wired on a dedicated radial circuit in 2.5mm² twin-and-earth, usually on a 16A device (20A only where the cable's installed rating allows). Isolated locally by a 20A double-pole switch (no fuse).
- Kitchen Appliances
- Appliances fitted into a kitchen extension that carry their own installation requirements: cooker hoods, boiling water taps, waste disposal units and water softeners.
- Macerator
- A small electric unit that grinds WC waste and pumps it through narrow-bore pipe to the soil stack, for a loft or basement ensuite that cannot reach a gravity drain. Approved Document G para 4.25 allows a macerator WC only where there is also access to a WC discharging directly to a gravity system, and the unit conforms to BS EN 12050-1 or -3; para 5.10 covers pumped washing appliances (BS EN 12050-2). Check the installation guide of the model you are quoted for fall, length and electrical requirements.
- Thermostatic blending valve
- A physical valve that mixes hot and cold water to a controlled safe temperature. Used as scald protection at baths, showers, and basins (TMV2/TMV3 rated) and to lower boiler flow temperature for UFH circuits.
- Tundish
- The visible air-gap fitting where the discharge pipe from an unvented cylinder's safety devices ends before running on to a safe drain. Approved Document G requires discharge from safety devices to be safely conveyed to where it is visible, and the tundish is that visible point. Awkward routing of the discharge pipe is one reason an unvented cylinder in an awkward spot costs more.
- Unvented hot water cylinder
- A hot water cylinder that stores mains-pressure hot water without a cold water header tank. Installation is legally restricted to competent persons under Part G of Building Regulations, with specific discharge pipework and safety valve requirements.
- Water softener
- A unit that removes limescale-causing minerals from mains water using ion exchange. Requires plumbing into the cold water supply before the kitchen run, typically under the sink or in a utility room. Unit £500–£1,200, installation £150–£400. Must be specified at first-fix plumbing stage.